Preliminary HVAC Cooling Capacity Rule of Thumb (Verify w/ Manual J)
Worked Example: 1,800 sq ft well-insulated home ÷ 600 = 3.0 Tons (36,000 BTU/hr)
For HVAC contractors and mechanical technicians
Present equipment SEER2 ratings, AHRI matched coils, ductwork transitions, crane or electrical exclusions, and parts-vs-labor warranties cleanly.
Free to use - No signup - PDF + PNG
What you send
Proposal
Your Business
#4821
Prepared for Rachel Donovan
Project 3-ton 16 SEER2 split heat pump system replacement
Pre-filled — just change names and prices.
Verify tonnage sizing, static pressure, line-set compatibility, and attic access before issuing a fixed HVAC quote.
Verify conditioned square footage, window orientation, and duct capacity instead of blindly swapping an oversized existing unit.
Measure supply/return static pressure (target <= 0.50 in. WC) to flag restrictive return grilles or crushed attic flex ducts before quoting.
Verify copper suction/liquid diameter matches new R-454B/R-32/R-410A condenser specs and inspect buried/chased line runs.
Check outdoor disconnect ampacity and indoor air-handler electric heat-strip breaker sizing against existing main panel spare slots.
Confirm primary PVC drain pitch, cleanout tee, auxiliary safety drain pan over finished ceilings, and code float cutoff switch.
Measure attic pull-down ladder width (>= 22.5 in.) or check crane lift access and municipal HERS/duct-test inspection requirements.
BTU/tonnage benchmarks, AHRI system matching, and mechanical crew hours.
Worked Example: 1,800 sq ft well-insulated home ÷ 600 = 3.0 Tons (36,000 BTU/hr)
Worked Example: 3-Ton (1,200 CFM) ÷ 300 FPM = 4.0 sq ft net return filter grille area
| Trade Task / Scope | Standard Labor Output | Material Coverage / Waste | Prep & Complexity Factor |
|---|---|---|---|
| Split Heat Pump / AC + Air Handler Swap (Same Footprint) | 10 – 14 crew hrs (2-tech) | Matched condenser/coil + plenum/pad kit | +30% for tight attic knee-wall clearance |
| Single-Zone Ductless Mini-Split Installation | 6.5 – 9.0 crew hrs | 1 indoor/outdoor kit + UV line hide | +2.5 hrs if dedicated 230V circuit pull needed |
| Custom Sheet-Metal Supply/Return Plenum Transition | 2.5 – 4.0 hrs | 26-ga galvanized + R-8 ductboard/liner | Sealed w/ UL-181 mastic & foil tape |
| Deep Vacuum & Subcooling Commissioning | 1.5 – 2.5 hrs | Nitrogen + refrigerant trim weigh-in | Target < 500 microns with 15-min decay hold |
Replace vague hvac line items that trigger surprise charges or unpaid rework with clear, measurable scope language.
| Dispute Trigger / Scope Area | Ambiguous Quote Wording (Avoid) | Why It Causes Disputes | Transparent Quote Alternative (Use This) |
|---|---|---|---|
| System Matching & Model Transparency | Install new 3-ton 16 SEER central air system — $8,900 | Does not confirm condenser/coil AHRI matching, refrigerant line replacement vs. flush, or exact outdoor/indoor model numbers. | Supply & install AHRI-matched 3-Ton 16 SEER2 Split Heat Pump (Model #[Outdoor] + Air Handler #[Indoor]), nitrogen-flush existing 3/4"×3/8" copper lines, new brazed filter drier, condenser pad, and disconnect whip. |
| Attic Flood & Condensate Protection | Connect indoor unit to existing drain pipe | If primary attic drain clogs years later without a secondary overflow pan and float cutoff switch, ceiling drywall collapses. | Includes new galvanized secondary drain pan under attic air handler, wired float-switch automatic cutoff safety, and pitched 3/4" PVC primary drain with cleanout tee. |
| OEM Parts vs. Service Labor Warranty | Includes full 10-year system warranty | Clients believe a failing blower in year 6 is 100% free, when manufacturers only cover the part while labor and refrigerant cost $450–$900. | Includes 10-Year Manufacturer Registered OEM Parts Warranty + 2-Year Contractor Workmanship & Refrigerant Labor Warranty. Diagnostic trip and labor fees after Year 2 are billed at standard service rates. |
Copy these transparent, plain-English clauses directly into your hvac proposal terms to protect both contractor and client from unforeseen defects, supply shifts, and warranty disputes.
EXISTING DUCTWORK BOUNDARY: This proposal connects to your existing supply and return duct system via new sealed sheet-metal plenum transitions. Pre-existing leaky trunks, disconnected attic runs, or undersized returns limiting airflow beyond manufacturer static pressure specs will be flagged with repair options before startup.
AHRI & COMMISSIONING STANDARD: Equipment is supplied as an AHRI-matched condenser and indoor coil/air handler pair. Our crew performs EPA refrigerant recovery, nitrogen-purged brazing, deep vacuum evacuation below 500 microns, and documented superheat/subcooling verification at startup.
WARRANTY SEPARATION: Manufacturer 10-year registered OEM warranty covers defective equipment components only. Our 2-year contractor workmanship warranty covers installation labor, brazed joints, and drain tie-ins. Routine filter changes, clogged condensate lines, and post-year-2 OEM warranty processing/refrigerant labor are excluded.
How it works
Pick an HVAC preset
Start with a heat pump split changeout, furnace replacement, or duct sealing.
Add specs & exclusions
Enter SEER2 tonnage, line-set flush, condensate pump, and permit rows.
Download PDF or PNG
Deliver a clean comparison-ready quote right from the homeowner's kitchen table.
Trade Guide
Homeowners shopping for a $7,000 to $14,000 HVAC replacement rarely understand why two 3-ton quotes vary by $3,500. A transparent proposal bridges that gap by naming the exact AHRI-matched condenser and indoor coil/air-handler model numbers, SEER2 and HSPF2 ratings, refrigerant type, and whether existing copper line sets are replaced or nitrogen-flushed and pressure-tested.
Prevent installation-day change orders by auditing static pressure, condensate drainage, attic access, and high-voltage wiring before quoting. Explicitly itemize custom sheet-metal plenum transitions, float-switch flood protection, permit/HERS testing requirements, and the exact boundary between OEM parts warranties and contractor labor coverage.
Use these typical cost baselines to price your hvac bids competitively and transparently.
| Service / Scope | Typical Range | Billing Model | Scope Details |
|---|---|---|---|
| 3-Ton Split Heat Pump / AC + Air Handler Swap | $7,200 - $12,800 | Turnkey matched system install | Includes AHRI coil, new pad, disconnect whip, vacuum test & EPA haul-away. |
| 80% / 96% AFUE Gas Furnace Replacement | $3,800 - $6,500 | Turnkey unit + flue/gas tie-in | Includes PVC/metal flue transition, gas sediment trap & startup combustion check. |
| Ductless Mini-Split Single-Zone Install | $3,400 - $5,500 | Per indoor head + line hide | Includes wall mount condenser, 25ft insulated line set & condensate drain. |
| Supply/Return Plenum & Duct Modification | $850 - $2,100 | Material + fabrication labor | Custom insulated sheet-metal transition, manual dampers & mastic air sealing. |
Yes — create separate proposals or clear optional add-on rows comparing equipment price, efficiency tier, and variable-speed comfort.
State clearly that your quote connects to existing ductwork via new plenum transitions, and list undersized trunk replacement or asbestos duct remediation separately.
Specify whips/disconnect box swaps explicitly and note whether crane lifts or dedicated electrical circuit pulls are excluded.
Clarify upfront that OEM parts coverage (typically 5–10 years once registered) covers replacement components, while diagnostic and refrigerant recovery labor follows your written workmanship window.
Yes — build and export unlimited HVAC proposals locally in your browser.
Open the free editor — no signup. Download PDF for email or PNG for texting.
Create proposal nowContinue your hvac quoting workflow with companion field protocols, estimation guides, and adjacent trade generators.
Structure AHRI-matched condenser/coil changeouts and OEM parts vs. labor coverage.
Separate 10-year manufacturer OEM parts warranties from service labor terms.
Measure attic pull-down clearances, return grilles, and condensate float safety.
Align 240V disconnect sizing and dedicated heat-strip breakers on changeout day.