For HVAC contractors and mechanical technicians

An HVAC proposal
built on load specs, not guesswork.

Present equipment SEER2 ratings, AHRI matched coils, ductwork transitions, crane or electrical exclusions, and parts-vs-labor warranties cleanly.

Free to use - No signup - PDF + PNG

What you send

A one-page proposal clients actually read.

  • Equipment & labor separated. List condenser/furnace model numbers apart from installation crew hours.
  • AHRI & SEER2 clarity. Document exact tonnage, efficiency ratings, and thermostat specs on-page.
  • Crane & electrical terms. Specify rooftop crane lifts or dedicated high-voltage disconnects upfront.
  • Clear warranty boundaries. Distinguish 10-year manufacturer parts from your workmanship guarantee.

Proposal

Your Business

#4821

Prepared for Rachel Donovan

Project 3-ton 16 SEER2 split heat pump system replacement

3-ton 16 SEER2 heat pump condenser + variable air handler × 1$4950.00
Installation accessories, sheet-metal plenum & line-set prep × 1$890.00
Licensed HVAC installation, EPA recovery & commissioning × 12$1860.00
Total$7700.00
Open the editor with this template

Pre-filled — just change names and prices.

Field Standard • On-Site Audit

Pre-Bid HVAC Load, Duct & Mechanical Audit

Verify tonnage sizing, static pressure, line-set compatibility, and attic access before issuing a fixed HVAC quote.

0 / 6 On-Site Checks Verified
  • ACCA Manual J Load & Existing Tonnage Check

    Verify conditioned square footage, window orientation, and duct capacity instead of blindly swapping an oversized existing unit.

  • Total External Static Pressure & Duct Sizing Check

    Measure supply/return static pressure (target <= 0.50 in. WC) to flag restrictive return grilles or crushed attic flex ducts before quoting.

  • Refrigerant Line-Set Sizing & Flush vs. Replace Audit

    Verify copper suction/liquid diameter matches new R-454B/R-32/R-410A condenser specs and inspect buried/chased line runs.

  • Electrical Disconnect, Wire Gauge & Breaker Audit

    Check outdoor disconnect ampacity and indoor air-handler electric heat-strip breaker sizing against existing main panel spare slots.

  • Condensate Drain Slope, Auxiliary Pan & Float Switch

    Confirm primary PVC drain pitch, cleanout tee, auxiliary safety drain pan over finished ceilings, and code float cutoff switch.

  • Attic Scuttle Clearance, Rooftop Rigging & Permits

    Measure attic pull-down ladder width (>= 22.5 in.) or check crane lift access and municipal HERS/duct-test inspection requirements.

Technical Benchmarks • Zero Hidden Markups

Job Costing & Material Estimation Standard

BTU/tonnage benchmarks, AHRI system matching, and mechanical crew hours.

Preliminary HVAC Cooling Capacity Rule of Thumb (Verify w/ Manual J)

Conditioned Sq Ft ÷ 500–600 sq ft/ton (adjusted for climate, insulation & ceiling height)

Worked Example: 1,800 sq ft well-insulated home ÷ 600 = 3.0 Tons (36,000 BTU/hr)

Minimum Return Grille Free Area Target

System CFM (400 CFM × Tons) ÷ 300–400 FPM Face Velocity

Worked Example: 3-Ton (1,200 CFM) ÷ 300 FPM = 4.0 sq ft net return filter grille area

Trade Task / ScopeStandard Labor OutputMaterial Coverage / WastePrep & Complexity Factor
Split Heat Pump / AC + Air Handler Swap (Same Footprint)10 – 14 crew hrs (2-tech)Matched condenser/coil + plenum/pad kit+30% for tight attic knee-wall clearance
Single-Zone Ductless Mini-Split Installation6.5 – 9.0 crew hrs1 indoor/outdoor kit + UV line hide+2.5 hrs if dedicated 230V circuit pull needed
Custom Sheet-Metal Supply/Return Plenum Transition2.5 – 4.0 hrs26-ga galvanized + R-8 ductboard/linerSealed w/ UL-181 mastic & foil tape
Deep Vacuum & Subcooling Commissioning1.5 – 2.5 hrsNitrogen + refrigerant trim weigh-inTarget < 500 microns with 15-min decay hold
Scope Clarity • Dispute Prevention

Common Quoting Ambiguities vs. Transparent Alternatives

Replace vague hvac line items that trigger surprise charges or unpaid rework with clear, measurable scope language.

Dispute Trigger / Scope AreaAmbiguous Quote Wording (Avoid)Why It Causes DisputesTransparent Quote Alternative (Use This)
System Matching & Model Transparency
Install new 3-ton 16 SEER central air system — $8,900
Does not confirm condenser/coil AHRI matching, refrigerant line replacement vs. flush, or exact outdoor/indoor model numbers.

Supply & install AHRI-matched 3-Ton 16 SEER2 Split Heat Pump (Model #[Outdoor] + Air Handler #[Indoor]), nitrogen-flush existing 3/4"×3/8" copper lines, new brazed filter drier, condenser pad, and disconnect whip.

Attic Flood & Condensate Protection
Connect indoor unit to existing drain pipe
If primary attic drain clogs years later without a secondary overflow pan and float cutoff switch, ceiling drywall collapses.

Includes new galvanized secondary drain pan under attic air handler, wired float-switch automatic cutoff safety, and pitched 3/4" PVC primary drain with cleanout tee.

OEM Parts vs. Service Labor Warranty
Includes full 10-year system warranty
Clients believe a failing blower in year 6 is 100% free, when manufacturers only cover the part while labor and refrigerant cost $450–$900.

Includes 10-Year Manufacturer Registered OEM Parts Warranty + 2-Year Contractor Workmanship & Refrigerant Labor Warranty. Diagnostic trip and labor fees after Year 2 are billed at standard service rates.

Mutual Consent • Copyable Contract Terms

Fair Quoting & Scope Protection Clauses

Copy these transparent, plain-English clauses directly into your hvac proposal terms to protect both contractor and client from unforeseen defects, supply shifts, and warranty disputes.

Performance Clarity

Existing Ductwork Static Pressure Disclaimer

EXISTING DUCTWORK BOUNDARY: This proposal connects to your existing supply and return duct system via new sealed sheet-metal plenum transitions. Pre-existing leaky trunks, disconnected attic runs, or undersized returns limiting airflow beyond manufacturer static pressure specs will be flagged with repair options before startup.

Quality Assurance

AHRI Match & Refrigerant Commissioning Standard

AHRI & COMMISSIONING STANDARD: Equipment is supplied as an AHRI-matched condenser and indoor coil/air handler pair. Our crew performs EPA refrigerant recovery, nitrogen-purged brazing, deep vacuum evacuation below 500 microns, and documented superheat/subcooling verification at startup.

Fair Warranty

OEM Parts vs. Contractor Labor Warranty Boundary

WARRANTY SEPARATION: Manufacturer 10-year registered OEM warranty covers defective equipment components only. Our 2-year contractor workmanship warranty covers installation labor, brazed joints, and drain tie-ins. Routine filter changes, clogged condensate lines, and post-year-2 OEM warranty processing/refrigerant labor are excluded.

How it works

Three steps, two minutes.

01

Pick an HVAC preset

Start with a heat pump split changeout, furnace replacement, or duct sealing.

02

Add specs & exclusions

Enter SEER2 tonnage, line-set flush, condensate pump, and permit rows.

03

Download PDF or PNG

Deliver a clean comparison-ready quote right from the homeowner's kitchen table.

Trade Guide

What to Include in an Honest HVAC Changeout Proposal

Homeowners shopping for a $7,000 to $14,000 HVAC replacement rarely understand why two 3-ton quotes vary by $3,500. A transparent proposal bridges that gap by naming the exact AHRI-matched condenser and indoor coil/air-handler model numbers, SEER2 and HSPF2 ratings, refrigerant type, and whether existing copper line sets are replaced or nitrogen-flushed and pressure-tested.

Prevent installation-day change orders by auditing static pressure, condensate drainage, attic access, and high-voltage wiring before quoting. Explicitly itemize custom sheet-metal plenum transitions, float-switch flood protection, permit/HERS testing requirements, and the exact boundary between OEM parts warranties and contractor labor coverage.

Average Pricing & Benchmarks

Industry standard estimates (2026)

Use these typical cost baselines to price your hvac bids competitively and transparently.

Service / ScopeTypical RangeBilling Model
3-Ton Split Heat Pump / AC + Air Handler Swap$7,200 - $12,800Turnkey matched system install
80% / 96% AFUE Gas Furnace Replacement$3,800 - $6,500Turnkey unit + flue/gas tie-in
Ductless Mini-Split Single-Zone Install$3,400 - $5,500Per indoor head + line hide
Supply/Return Plenum & Duct Modification$850 - $2,100Material + fabrication labor

Common questions

Can I show multiple efficiency options (e.g., 14.3 vs 18 SEER2)?

Yes — create separate proposals or clear optional add-on rows comparing equipment price, efficiency tier, and variable-speed comfort.

How should existing ductwork defects be handled in a changeout quote?

State clearly that your quote connects to existing ductwork via new plenum transitions, and list undersized trunk replacement or asbestos duct remediation separately.

Are 240V electrical disconnects and crane lifts included?

Specify whips/disconnect box swaps explicitly and note whether crane lifts or dedicated electrical circuit pulls are excluded.

Does Manufacturer Parts Warranty cover labor after year one?

Clarify upfront that OEM parts coverage (typically 5–10 years once registered) covers replacement components, while diagnostic and refrigerant recovery labor follows your written workmanship window.

Is QuoteFast free with no account?

Yes — build and export unlimited HVAC proposals locally in your browser.

Ready to send your hvac proposal?

Open the free editor — no signup. Download PDF for email or PNG for texting.

Create proposal now